- Home/
- All Products
- Medical Supplies & Equipment
- All Sub-Categories
- IV Therapy
- Central Venous Catheter Kits
- Central Venous Catheter Kit



Compare
View Alternative
Teleflex Central Venous Catheter Kit 20, 22 Gauge Multi Lumen - Polyurethane
AK-16553 | USAMP#28958769
length
1-3/4 Inch, 5-1/8 Inch
Cart
Total Price
Request for Bulk Orders
Custom quotes are available for bulk purchases only.
Product Specification
Manufacturer SKU
AK-16553
Manufacturer
Teleflex
USAMP SKU
USAMP#28958769
Application
Central Venous Catheter Kit
UNSPSC Code
42221509
Country Of Origin
Unknown
Contents 1
(1) Multi-Lumen Indwelling Catheter: 5.5 Fr. X 5-1/8 Inch Radiopaque Polyurethane with Blue FlexTip®, Extension Line Clamps, Injection Site Caps, (1) Spring-Wire Guide: 0.018 Inch dia. X 17-3/4 Inch (Straight soft tip on one end - "J'' tip on other), (1) Introducer Needle: 21 Gauge X 1-1/2 Inch TW, (1) Catheter: 22 Gauge X 1-3/4 Inch Radiopaque over 25 Gauge RW Introducer Needle with 5 mL Luer-Slip Syringe, (1) Injection Needle: 25 Gauge X 1 Inch and 3 mL Luer-Lock Syringe, (1) Injection Needle: 25 Gauge X 1-1/2 Inch and 5 mL Luer-Slip Syringe, (1) Tissue Dilator, (1) 3 mL Applicator Pouch, 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi-Lite Orange™ Tint, (1) 5 mL Ampoule HCl, 1% Lidocaine Solution, (1) Clamp: Catheter, (1) Fastener: Catheter Clamp, (1) SharpsAway® Disposal Cup, (1) CSR Wrap, (1) Drape: 18 X 26 Inch with 3 Inch fenestration, (1) Scalpel: #11, (2) Gauze Pad(s): 2 X 2 Inch, (5) Gauze Pad: 4 X 4 Inch, (1) Suture: 3-0 Braided Silk with Straight Needle
Hcpcs
C1751
Material
Polyurethane, Radiopaque
Length
1-3/4 Inch, 5-1/8 Inch
Tube Type
Multi Lumen
Diameter
20, 22 Gauge
Cart
Total Price
Request for Bulk Orders
Custom quotes are available for bulk purchases only.
Talk to an Expert Now!
(786) 305-5899
24/7 Live Chat!
Chat Now
Compare Products
![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |
---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Teleflex | Teleflex | Teleflex | Teleflex | Teleflex | Teleflex Medical | Teleflex | Teleflex | Teleflex | Teleflex |
Brand | Arrow-Howes™ | Arrowg+ard Blue® | MAC™ | Arrowg+ard Blue Plus® | Arrowg+ard Blue® | Arrow | ||||
UNSPSC Code | 42221509 | 42221509 | 42221509 | 42221509 | 42221509 | 42221503 | 42221509 | 42221509 | 42221509 | 42221509 |
Country Of Origin | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown |
Usage | Single Use | Single Use | Single Use | Single Use | Disposable | Single Use | Single Use | Single Use | ||
Contents 1 | (1) Multi-Lumen Indwelling Catheter: 7 Fr. x 12 Inch (30 cm) Radiopaque Polyurethane with Blue FlexTip*, Extension Line Clamps, Injection Site Caps(1) Spring-Wire Guide: .032 Inch (.81 mm) dia. x 26-13/16 Inch (68 cm)(Straight Soft Tip on One End - "J" Tip on Other)(1) Introducer Needle: 18 Ga. x 2-1/2 Inch (6.35 cm) XTW(1) Catheter: 18 Ga. x 2-1/2 Inch (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle with 5 cc Luer-Slip Syringe(1) Injection Needle: 22 Ga. x 1-1/2 Inch (3.81 cm) and 5 cc Luer-Slip Syringe(1) Injection Needle: 25 Ga. x 1 Inch (2.54 cm) and 3 cc Luer-Lock Syringe(1) Tissue Dilator(1) 1 Applicator Pouch 2% ChloraPrep* One-Step Solution(1) 5 ml Ampule HCl, 1% Lidocaine Solution(1) Suture: 3-0 Braided Silk with Straight Needle(1) Clamp: Catheter(1) Fastener: Catheter Clamp(1) SharpsAway II* Locking Disposal Cup(1) CSR Wrap(1) Drape: 24 Inch x 36 | (1) Arrowg+ard Blue® Three-Lumen Catheter: 12 Fr. (4.1 mm OD) X 16 cm, (1)Spring-Wire Guide, Marked: .035 Inch (0.89 mm) dia. X 23-5/8 Inch (60 cm) (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer, (1) Catheter: 18 Ga. X 2-1/2 Inch (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle, (1) Injection Needle: 25 Ga. X 1 Inch (2.54 cm), (1) Blunt Fill Needle: 18 Ga. X 1-1/2 Inch (3.81 cm), (1) Pressure Transduction Probe, (1) Introducer Needle: 18 Ga. X 2-1/2 Inch (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe, (1) Injection Needle: 22 Ga. X 1-1/2 Inch (3.81 cm) and 5 mL Luer-Slip Syringe, (1) Syringes: 3 mL Luer-Lock, (1) Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm, (1) 5 mL 1% Lidocaine HCl Solution and Alcohol Prep, (1) 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi-Lite Orange™ Tint, (1) SharpsAway® Disposal Cup, (1) Drape 24 X 36 Inch with 4 Inch Fenestration, (1) #11 Scalpel, (2) 2 X 2 Inch Gauze Pad, (5) 4 X 4 Inch Gauze Pad (1) Suture: 3-0 Braided Silk with Straight Needle | (1) Two-Lumen Central Venous Access Device: 115 mm Radiopaque Polyurethane with 9 Fr. Distal Lumen, Integral Haemostasis Valve, Extension Line Clamps, (1) Spring-Wire Guide, Marked: 0.035 Inch dia. X 17-3/4 Inch (Straight Soft Tip on One End - "J'' Tip on Other) with Arrow Advancer™, (1) Catheter: 18 Gauge X 2-1/2 Inch Radiopaque over 20 Ga. RW Introducer Needle, (1) Pressure Transduction Probe, (1) Injection Needle: SafetyGlide™ 22 Gauge X 1-1/2 Inch and 5 mL Luer-Slip Syringe, (1) Injection Needle: SafetyGlide™ 25 Gauge X 1 Inch and 3 mL Luer-Lock Syringe, (1) Introducer Needle: Echogenic 18 Gauge X 2-1/2 Inch XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe, (1) Tissue Dilator, (1) 3 ml Applicator Pouch, 2% CHG and 70% IPA ChloraPrep® One-Step Solution with Hi-Lite Orange™ Tint, | Spring-Wire Guide, Marked: .032 Inch dia. x 23-5/8 Inch (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer™ | (1) Indwelling Catheter: 16 Ga. x 8 Inch (20 cm) Radiopaque Polyurethane with Integral Suture Wing(1) Spring-Wire Guide: .032 Inch (.81 mm) dia. x 17-13/16 Inch (45 cm) (Straight Soft Tip on End - "J" Tip on Other)(1) Catheter: 18 Ga. x 2-1/2 Inch (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle(1) Fastener: Catheter Clamp(1) Introducer Needle: 18 Ga. x 2-1/2 Inch (6.35 cm) XTW(1) Injection Needle: 22 Ga. x 1-1/2 Inch (3.81 cm)(1) Injection Needle: 25 Ga. x 1 Inch (2.54 cm)(2)Two: Syringe: 5 cc Luer-Slip(1) 3 Swabstick Foil Pack 10% Povid-Iodine(1) 5 ml Ampule HCl, 1% Lidocaine Solution(1) Tissue Dilator(1) Drape: 18 Inch x 26 Inch with 3 Inch fenestration(1) CSR Wrap(3) Gauze Pad(s): 2 Inch x 2 Inch(4) Gauze Pad(s): 4 Inch x 4 Inch(1) Scalpel: #11(1) Suture: 3-0 Silk with Straight Needle(1) SharpsAway® Disposal Cup | Spring-Wire Guide, Nitinol, Marked: 0.032 Inch dia. x 23-5/8 Inch (Straight Soft Tip on One End - "J" Tip on Other) with Arrow® GlideWheel™ Wire Advancer, Catheter: 18 Ga. x 2-1/2 Inch Radiopaque over 20 Ga. RW Introducer Needle, Injection Needle: SafetyGlide™2 25 Ga. x 1 Inch, Blunt Fill Needle: 18 Ga. x 1-1/2 Inch, Pressure Transduction Probe, Introducer Needle: Echogenic 18 Ga. x 2-1/2 Inch XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe, Injection Needle: SafetyGlide™2 22 Ga. x 1-1/2 Inch and 5 mL Luer-Slip Syringe, Syringes 3 mL Luer-Lock, Tissue Dilator: 8.5 Fr. x 10.2 cm, 3 Luer-Lock Pre-Filled Saline 10 mL Syringe, Lidocaine HCl 1% Solution 5 mL and Alcohol Prep, | (1) Multi-Lumen Indwelling Catheter: 7 Fr. X 8 Inch Pressure Injectable Radiopaque Polyurethane with Blue FleXTip®, ARROWg+ard Blue PLUS® Antimicrobial Surface Treatment, Extension Line Clamps, (1) Spring-Wire Guide, Marked: 0.032 Inch dia. X 23-5/8 Inch (Straight Soft Tip on One End - "J'' Tip on Other) with Arrow Advancer™, (1) Catheter: 18 Gauge X 2-1/2 Inch Radiopaque over 20 Gauge RW Introducer Needle, (1) Pressure Transduction Probe, (1) Injection Needle: SafetyGlide™ 22 Gauge X 1-1/2 Inch and 5 mL Luer-Slip Syringe,(1) Injection Needle: SafetyGlide™ 25 Gauge X 1 Inch and 3 mL Luer-Lock Syringe, (1) Introducer Needle: Echogenic 18 Gauge X 2-1/2 Inch XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe, | (1) Arrowg+ard Blue® Two-Lumen Catheter: 7 Fr. (2.5 mm OD) X 16 cm, Pressure Injectable, (1) Spring-Wire Guide, Marked: .025 Inch (0.64 mm) dia. X 23-5/8 Inch (60 cm) (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer, (1) Catheter: 20 Ga .X 1-3/4 Inch (4.45 cm) Radiopaque over 22 Ga. TW Introducer Needle, (1) Introducer Needle: Echogenic 18 Ga. X 2-1/2 Inch (6.35 cm) RW, (1)Injection Needle: SafetyGlide™1 25 Ga. X 1 Inch (2.54 cm), (1) Blunt Fill Needle: 18 Ga. X 1-1/2 Inch (3.81 cm), (1)Pressure Transduction Probe, (1) Introducer Needle: Echogenic 20 Ga. X 1-1/2 Inch (3.81 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe, (1) Injection Needle: SafetyGlide™1 22 Ga. X 1-1/2 Inch (3.81 cm) and 5 mL Luer-Slip Syringe, (1) Syringes: 3 mL Luer-Lock, (1) Tissue Dilator: 8.5 Fr. (2.8 mm) X 10.2 cm, (2) 10 mL Luer-Lock Pre-Filled Saline Syringe, (1) 5 mL 1% Lidocaine HCl Solution and Alcohol Prep, (1) 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with Hi-Lite Orange™ Tint, (1) SecondSite™ Adjustable Hub: Fastener, (1) SecondSite™ Adjustable Hub: Catheter Clamp, (1) SharpsAway® Disposal Cup, (1) SharpsAway® II Locking Disposal Cup, (1) Maximal Barrier Drape™ with 4 Inch Fenestration, (1) Towel, (1) Needle Holder, (1) Safety Scalpel: #11, (1) Checklist/CLIP Sheet, (1) Flow Rate Information Card with Injection Log, (1) Sterile Procedure Sign, (1) Medication Label: 1% Lidocaine, (2) 2 X 2 Inch Gauze Pad, (5) 4 X 4 Inch Gauze Pad, (1) Dressing: Tegaderm®3 10 cm x 12 cm, (1) Impervious Gown, (1) Dressing: BIOPATCH®4, (1) Bouffant Cap, (1) Mask with Eye Shield, (1) Suture: 3-0 Silk with Curved Needle, (1) Tubing±: 20 Inch (50 cm) Extension, (1) HemoHopper® Fluid Receptacle | (1) One-Lumen Catheter 24 Ga. (0.8 mm OD) x 9 cm, (1) Spring-Wire Guide: .018 Inch (0.46 mm) Dia. X 13-3/4 Inch (35 cm) (Straight Soft Tip on One End - "J" Tip on Other), (1) Introducer Needle: 21 Ga. X 1-1/2 Inch (3.81 cm) TW, (2) Syringes: 3 mL Luer-Lock, (1) SecondSite™ Adjustable Hub: Catheter Clamp, (1) Drape: 18 X 26 Inch (46 cm x 66 cm) with 3 Inch (7.6 cm) Fenestration, (1) #11 Scalpel, (1) Prep Sponge Swab, (3) 2 X 2 Inch Gauze Pad | (1) Indwelling Catheter: 16 Ga. x 8 Inch (20 cm) Radiopaque Polyurethane with Integral Suture Wing(1) Spring-Wire Guide: .032 Inch (.81 mm) dia. x 17-13/16 Inch (45 cm)(Straight Soft Tip on One End - "J" Tip on Other)(1) Catheter: 18 Ga. x 2-1/2 Inch (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle(1) Injection Needle: 20 Ga. x 1-1/2 Inch (3.81 cm) and 5 cc Luer-Slip Syringe(1) Injection Needle: 25 Ga. x 1 Inch (2.54 cm) and 3 cc Luer-Lock Syringe(1) Introducer Needle: 18 Ga. x 2-1/2 Inch (6.35 cm) XTW and 5 cc Luer-Slip Syringe(1) Tissue Dilator(1) 3 Swabstick Foil Pack 10% Povidone-Iodine(1) 5 ml Ampule HCl, 1% Lidocaine Solution(1) Clamp: Catheter(1) Fastener: Catheter Clamp(1) SharpsAway* Disposal Cup(3) Drape: 26 Inch x 18 Inch with adhesive(1) CSR Wrap(1) Scalpel: #11(3) Gauze Pad(s): 4 Inch x 4 Inch(3) Suture: 3-0 Nylon with Straight |
Contents 2 | Inch with 4 Inch fenestration(1) Safety Scalpel: #11(4) Staple Anchoring Devices(2) Gauze Pad(s): 2 Inch x 2 Inch(5) Gauze Pad(s): 4 Inch x 4 Inch | (1) 5 ml Ampoule HCl, 1% Lidocaine Solution, (1) Cath-Gard® Catheter Contamination Shield: 80 cm with TwistLock™ Adapter, (1) Obturator: 8 Fr., (1) Dust Cap: Non-Vented, (1) Dust Cap: Vented, (1) SharpsAway II™ Locking Disposal Cup, (1) SharpsAway® Disposal Cup, (1) CSR Wrap, (1) Maximal Barrier Drape™ with 4 Inch fenestration, (1) Towel, (1) Needle Holder, (1) Safety Scalpel: #11, (1) Checklist/CLIP Sheet, (1) Medication Label: 1% Lidocaine, (1) Sterile Procedure Sign, (1) Stopcock: 4-way High-Flow, (1) Gauze Pad(s): 2 X 2 Inch, (1) Gauze Pad(s): 3 X 3 Inch, (1) Gauze Pad(s): 4 X 4 Inch, (1) Surgical Apparel: Bouffant Cap, (1) Surgical Apparel: Impervious Gown, (1) Surgical Apparel: Mask with Eye Shield, (1) Suture: 3-0 Silk with Curved Needle, (1) Tubing: 20 Inch Extension | Catheter: 18 Ga. x 2-1/2 Inch Radiopaque over 20 Ga. RW Introducer Needle, Pressure Transduction Probe, Injection Needle: SafetyGlide™2 22 Ga. x 1-1/2 Inch and 5 mL Luer-Slip Syringe, Injection Needle: SafetyGlide™2 25 Ga. x 1 Inch and 3 mL Luer-Lock Syringe, : Introducer Needle: Echogenic 18 Ga. x 2-1/2 Inch XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe, Tissue Dilator, 3 ml Applicator Pouch 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint, Suture: 3-0 Silk with Curved Needle | 2 Applicators 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint 3mL, SecondSite™ Adjustable Hub: Fastener, SecondSite™ Adjustable Hub: Catheter Clamp, SharpsAway® Disposal Cup, SharpsAway® II Locking Disposal Cup, Maximal Barrier Drape™ with 4 Inch Fenestration, Towel, Needle Holder, Safety Scalpel #11, Checklist/CLIP Sheet, Sterile Procedure Sign, Medication 1% Lidocaine Label, 2 Gauze Pad: 2 x 2 Inch, 5 Gauze Pad 4 x 4 Inch, Surgical Impervious Gown, Tegaderm® Dressing 4 CHG 3-1/2 x 4-1/2 Inch, Transducer Cover: 14 cm x 147 cm, Surgical Mask with Eye Shield, Surgical Bouffant Cap, 3-0 Silk Suture with Curved Needle, Tubing±: 20 Inch Extension, HemoHopper® Fluid Receptacle | (1) Tissue Dilator, (2) 10 ml Luer-Lock Pre-Filled Saline Syringe, (1) 3 ml Applicator Pouch, 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint, (1) 5 ml Ampoule HCl, 1% Lidocaine Solution, (1) Foil Pack 62% Alcohol Hand Gel, (1) Fastener: Catheter Clamp, (1) SharpsAway II™ Locking Disposal Cup, (1) SharpsAway® Disposal Cup, (2) CSR Wrap, (1) MaXimal Barrier Drape™ with 4 Inch fenestration, (1) Towel, (1) Needle Holder, (1) Safety Scalpel: #11, (1) Checklist/CLIP Sheet, (1) Flow Rate Information Card with Injection Log, (1) Medication Label: 1% Lidocaine, (1) Sterile Procedure Sign, (1) Dressing: BIOPATCH®4, (1) Dressing: Tegaderm® 10 X 12 cm, (2) Gauze Pad(s): 2 Inch X 2 Inch, (2) Gauze Pad(s): 3 Inch X 3 Inch, (5) Gauze Pad(s): 4 Inch X 4 Inch, (1) Surgical Apparel: Bouffant Cap, (1) Surgical Apparel: Impervious Gown, (1) Surgical Apparel: Mask with Eye Shield, (1) Suture: 3-0 Silk with Curved Needle | Needle(1) | ||||
Material | Radiopaque Polyurethane | Radiopaque | Pressure Injectable Radiopaque Polyurethane | Radiopaque Polyurethane | Pressure Injectable Radiopaque Polyurethane | Radiopaque Polyurethane | Radiopaque Polyurethane | |||
Length | 12 Inch | 16 cm | 2-1/2 Inch | 8 Inch | 8 Inch | 20 cm | 2-1/2 Inch, 8 Inch | 16 cm | 9 cm | 8 Inch |
Style | Blue FlexTip* | Blue FlexTip* | ||||||||
Tube Type | Triple Lumen | Triple Lumen | Two Lumen | Triple Lumen | Single Lumen | Tri Lumen | Multi Lumen | Double Lumen | Single Lumen | Single Lumen |
Diameter | 7 Fr. | 12 Fr. | 12 Gauge, > 9 Fr. | 7 Fr. | 16 Gauge | 7 Fr. | 16, 18 Gauge | 7 Fr. | 24 Gauge | 16 Gauge |
Sterility | Sterile | Sterile | Sterile | Sterile | ||||||
User | Adult | Adult | Adult | Adult | ||||||
Coating | Arrowg+ard Blue Antimicrobial | ARROWg+ard Blue PLUS® Antimicrobial Surface Treatment | Arrowg+ard Blue Antimicrobial | |||||||
Hcpcs | C1892 | C1751 | C1751 | |||||||
Contents 3 | 5 ml Ampule HCl, 1% Lidocaine Solution, Fastener: Catheter Clamp, SharpsAway II™ Locking Disposal Cup, 3 CSR Wraps, Maximal Barrier Drape™ with 4 Inch Fenestration, Towel, Needle Holder, Safety Scalpel: #11, CVC Maximal Barrier Guide Card, Flow Rate Information Card with Injection Log, Medication Label: 1% Lidocaine, Sterile Procedure Sign, 2 Gauze Pads: 2 x 2 Inch, 5 Gauze Pads: 4 x 4 Inch, Bouffant Cap, Impervious Gown, Mask with Eye Shield |